Philips Energy Advantage CDM lamps with AllStart™ Technology



Want to Know more about CMH? Check out our CMH FACT PAGE
 


We are the Only Company to Pre-burn all lamps!
Each Receive 3, 12 hour burn cycles to ensure the cermets seal is seated properly.
This is 100% Needed as there is a High initial failure rate.
 If this is done you are sure to have a full life from your lamp.
 
US Customers
$10.00 Flat Rate Shipping on any QTY Lamp Orders*
If ordering a ballast also we have to charge a Little More.
205 Watt Universal Burn
Use On
250 Watt Metal Halide Ballast
$78.00
CDM205/U/O/4K EA Allstart
400 Watt Universal Burn
Use On
400 Watt Metal Halide Ballast
$78.00
CDM330/U/O/4K EA Allstart
Check out our Electronic & Digital Ballast's Fact Page If you have been using the Eye Hortilux Blue because it was your only option now you have a choice Blue or Red Dominate SPD

May We Recommend A Ballast Kit.
Philips Advance Brand
+
5 Year Warranty
 
Check out our Photo Gallery
It is a Mess of Photos for now however
its fun to checkout.

 

Check Out our YouTube Page

 

     

 

 Philips Energy Advantage CDM AllStart
.
Direct retrofit with immediate energy savings!
..
Use on Metal Halide Ballast's
 

Philips Energy Advantage CDM lamps with AllStart™ Technology

A high-efficiency protected “O” rated CDM lighting solution that provides energy savings without  compromising light quality.

  • UPDATED 1.5 Year Warranty
     

  • Direct retrofit lamp to both probe and pulse start magnetic ballasts
     
  • Utilizes 175, 250, 400 Watt Metal Halide Probe Or Pulse Start Ballasts
     
  • A true universal operation that does not affect lamp life
     
  • Long life 20,000 hrs rated average life
     
  • Energy savings up to 18%*
     
  • 100 Lumen Per Watt
     
  • Excellent Color Stability, High CRI 85 - 90
     

  • 80%+ Lumen Maintenance Stays brighter, longer.
     

  • No Shut Off Required
     

  • Ideal for 24-hour a day, 7-day a week operations
    (Re-lamp fixtures at or before the end of rated life)
     

  • Patented Coil Design Offers Protection
    for Open Fixture Rating
     

  • Ideal for indoor and outdoor applications
    of industrial facilities and warehouses

    * 330W CDM lamp with AllStart™Technology compared to 400W quartz Metal Halide lamp.

    Note These Do not operate on HPS High Presure Sodium Ballasts.
    See the HPS Retro-White CMH Page Link

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Philips Energy Advantage CDM lamps with AllStart™ Technology. A high-efficiency protected “O” rated CDM lighting solution that provides energy savings without compromising light quality.

Colors are brighter and more vivid under MasterColor®
HPS-Retro White™ than they appear under standard
 High Pressure Sodium lamps.

Vertical and  Horizontal Operation Lamps are available

The Ceramic Discharge Arc Tube is More Robust than the Traditional Quartz Arc Tube Utilized in Metal Halide Lamps Witch  provides.
–Superior lumen maintenance
–Crisp, bright white light with superior color rendering
–Superior color stability over time and lamp to lamp color consistency

Patented "Coil Design"
–Rated for open fixture use
–Ability to operate 24/7 without shut off 3

We are the Only Company to Pre-burn all lamps!
Each Receive 3, 12 hour burn cycles to ensure the cermets seal is seated properly.
This is 100% Needed as there is a High initial failure rate.
 If this is done you are sure to have a full life from your lamp.


 

 

Phlips Energy Advantage CDM AllStart Lamps

Electrical, Technical, & Ordering Information ~ Currently there is NO Cross To other MFR at this time. ~ All Data Subject to change without Notice.
PDF Data Sheet

Clear Lens

 
Product
Number
Ordering Code Nom.
Watts
Bulb Base Std.
Pkg.
Qty.

ANSI
Ballast Code

LCL
(In)
MOL
(In)
Color
Temp
(Kelvin)
CRI Rated
Avg. Life
(Hrs)1
Approx
Initial
Lumens2,3
Approx
Mean
Lumens2,3
 
CDM145/U/O/4K/ED28 EA AllStart 145 5 85⁄16 4,000 87 13,500 10,125
23256-1 CDM205/U/O/4K EA Allstart 205 ED28 6 C184 5 85⁄16 4,100 85 20,000 20,500 15,600 $78.00

23259-5 CDM330/U/O/4K EA Allstart 330 ED37 6 C185 7 111⁄2 4,100 90 20,000 33,000 26,400 $78.00

Coated Lens IE Frosted (Not as intense, Provides a Glowing affect.

Product
Number
Ordering Code Nom.
Watts
Bulb Base Std.
Pkg.
Qty.

ANSI
Ballast Code

LCL
(In)
MOL
(In)
Color
Temp
(Kelvin)
CRI Rated
Avg. Life
(Hrs)1
Approx
Initial
Lumens2,3
Approx
Mean
Lumens2,3
CDM145/C/U/O/4K/ED28 EA AllStart 145 5 85⁄16 4,000 87 12,500 9,600
23692-7 CDM205/C/U/O/4K EA Allstart 205 ED28 6 C184 5 85⁄16 4,100 85 20,000 18,000 14,400
23693-5 CDM330/C/U/O/4K EA Allstart 330 ED37 6 C185 7 111⁄2 4,100 85 20,000 31,000 22,400

CDM145 Uses Ansi Ballasts M57,M132, M152
CDM205 Uses Ansi Ballasts M58/O M138/O M153/O
CDM330 Uses Ansi Ballasts M59/O M165/O M128/O M135/O M155/O M172/O

 

 
R
RECOMMENDED WARNINGS, CAUTIONS, AND OPERATING INSTRUCTIONS
m
WARNING
: "These lamps can cause serious skin burn and eye inflammation from short wave ultraviolet radiation if outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Certain lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available." This lamp complies with FDA radiation performance standard 21 CFR subchapter J. (USA:21CFR 1040.30 Canada: SOR/ DORS/80-381).

If the outer bulb is broken or punctured, turn off at once and replace the lamp to avoid possible injury from hazardous short wave ultraviolet radiation. Do not scratch the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter. A partial vacuum in the outer bulb may cause glass to fly if the envelope is struck.

WARNING
: The arc-tube of metal halide lamps are designed to operate under high pressure and at temperatures up to 1000º C and can unexpectedly rupture due to internal or external factors such as a ballast failure or misapplication. If the arc-tube ruptures for any reason, the outer bulb may break and pieces of extremely hot glass might be discharged into the surrounding environment. If such a rupture were to happen, THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.

These lamps are designed to retain all the glass particles should an arc tube rupture occur. The following operating instructions are recommended to minimize these occurrences. RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE.
Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture.

This lamp contains an arc tube with a filling gas containing Kr-85 and is distributed by Philips Lighting Company, a division of Philips Electronics North America Corporation, Somerset, New Jersey, 08875.
CAUTION: TO REDUCE THE RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE RESULTING FROM AN ARC-TUBE RUPTURE THE FOLLOWING LAMP OPERATING INSTRUCTIONS MUST BE FOLLOWED:
LAMP OPERATING INSTRUCTIONS: 1) RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE. Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture.
2) Before lamp installation/replacement, shut power off and allow lamp and fixture to cool to avoid electrical shock and potential burn hazards.
3) Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage limits recommended by ballast manufacturer.
A. Operate lamp only within specified limits of operation.
B. For total supply load refer to ballast manufacturers electrical data.
4) Periodically inspect the outer envelope. Replace any lamps that show scratches, cracks or damage.
5) If a lamp bulb support is used, be sure to insulate the support electrically to avoid possible decomposition of the bulb glass.
6) Protect lamp base, socket and wiring against moisture, corrosive atmospheres and excessive heat.
7) Time should be allowed for lamps to stabilize in color when turned on for the first time. This may require several hours of operation, with more than one start. Lamp color is also subject to change under conditions of excess vibration or shock, and color appearance may vary between individual lamps.
8) Lamps may require 10 to 20 minutes to re-light if there is a power interruption.
9) Take care in handling and disposing of lamps. If an arc tube is broken, avoid skin contact with any of the contents or fragments.

 

Philips Energy Advantage CDM lamps with AllStartTechnology Specifications:

Rated Approx. Approx. Color

Ordering Bulb LCL MOL Avg. Life Initial Mean Temp Burn

Bulb Base Code Watts Finish (In.) (In.) (Hrs.)1 Lumens2 Lumens3 CRI (K) Position

ED28 EX39 Excl. Mog. CDM145/U/O/4K/ED28 EA AllStart 145 Clear 5 85⁄16 20,000 13,500 10,125 87 4000 Universal

ED28 EX39 Excl. Mog. CDM145/C/U/O/4K/ED28 EA AllStart 145 Coated — 85⁄16 20,000 12,500 9,600 87 4000 Universal

ED28 EX39 Excl. Mog. CDM205/U/O/4K EA AllStart 205 Clear 5 85⁄16 20,000 19,500 15,600 85 4100 Universal

ED28 EX39 Excl. Mog. CDM205/C/U/O/4K EA AllStart 205 Coated — 85⁄16 20,000 18,000 14,400 85 4100 Universal

ED28 EX39 Excl. Mog. CDM330/U/O/4K/ED28 EA AllStart 330 Clear 5 85⁄16 20,000 33,000 26,400 90 4000 Universal

ED37 EX39 Excl. Mog. CDM330/U/O/4K EA AllStart 330 Clear 7 111⁄2 24,000 33,000 26,400 90 4000 Universal

ED37 EX39 Excl. Mog. CDM330/C/U/O/4K EA AllStart 330 Coated — 111⁄2 24,000 31,000 24,800 90 4000 Universal

 

First Set is if you use your current ballast.
2nd Row for each KW is if you purchase HPS Ballast.

© Advanced Technology Solutions, LLC ~ Lighting Division, all rights protected.
Any other Images Trademarks & Copyrighted Material used IS  the property of their respective owners.

Warning all Images and Cell/Tables have been Embedded with our Information
Prevent Competitors from Steeling Information we worked compiled.
Customers are Fully Authorized to Post our information in Public Forums
As long as we are Given Credit or Linked by Poster.